Shear Connector 1″ Diameter
1″ DIAMETER SHEAR CONNECTORS STUD SPECIFICATIONS (inches) |
||
---|---|---|
D | H | A |
1 | 1-5/8 | 1/2 |
1″ FERRULE SPECIFICATIONS (inches) |
||||||
---|---|---|---|---|---|---|
FERRULE CODE |
D | B | G | M | TYPE | |
FF-100 | 1.620 | 1.416 | .633 | .835 | Flat Surface |
1″ DIAMETER SHEAR CONNECTORS (inches) |
||
---|---|---|
STANDARD LENGTH |
PART NUMBER |
WEIGHT (lbs.) PER 1000 |
4-1/4 | SC-1×0425 | 1133 |
5-1/4 | SC-1×0525 | 1383 |
6-1/4 | SC-1×625 | 1600 |
8-1/4 | SC-1×0825 | 2050 |
9-1/4 | SC-1×0925 | 2225 |
10-1/4 | SC-1×1025 | 2428 |
Ferrules
All orders for studs include ferrules.Mechanical Properties
TENSILE STRENGTH – 65,000 PSI MIN (450 MPa)
YIELD STRENGTH (.2% OFFSET) – 51,000 PSI MIN (350 MPa)
ELONGATION (% IN 2 IN.) 20% (% IN 5x DIA.) 15% MIN.
REDUCTION OF AREA 50% MIN
Material
LOW CARBON STEEL
ASTM A108, 1010-1020.
Also available in stainless steel.
Application
Shear connectors are used to tie concrete to steel beams and to resist shear loading between the concrete slab and the steel beam in composite construction.
Other Notes
Custom lengths available
Stud Length Reduction
Specified lengths are before weld. Approximate length reduction after
welding is 1/4″